MAGNETIC LEVEL SWITCH - TOP MOUNTED ( TYPE : CLT-400 ) |
CRISTAL 'GEM' Level Switch (top mounted 1ype) facilitates any number of pre-determined level controls initiating audio-visual signals with a single unit. It is designed to provide reliable operation in severe industrial applications. The unit consists of a vertical guide pipe (stem) within which are located the sensor switches, magnetic float sliding over the stem according to the level in the tank, switch terminal housing (head) and necessary mounting connection.
The Switch operates on the basis of the float principle with magnetic transmission (permanent magnet-reed switch).
The switch is encapsulated in the stem and it is actuated by a permanent magnet within the float.
SPECIFICATIONS
Float Stem &
all wetted parts
Switch
Terminal Head
Conduit connection
Process connection
Stem length
No. of switch stations & locations
Switch Differential-fixed
Max. Working Pressure 15 Kg/cm2
|
SS-304 1 SS-316
Hermetically sealed magnetically operated reed switch with Rhodium contacts completely isolated from medium having SPST 1 SPDT contacts.
Current rating 0.5 A at 240 V AC std. Switch rating 15 watts. Higher ratings upto 250 watts optional.
Cast Aluminium weather - proof. Flame-proof enclosure on request.
3/4" ET std.
Square flanged to 83 mm PCD of SS materials std.
Any length up to 3 meters.
As per customer requirements.
3 to 5 mm. Higher differential up to 15 mm on request
Max. Working Temperature |
|
Salient Features
* Because the switches operate on the principle of magnetic - flux coupling with no mechanical connections, fluid contamination of switch components cannot occur.
* Only one moving component exists-the no wear float.
* Reliable in operation because of the large gap between the slide tube of the float and the fixed guide tube.
* Insensitive to dirt particles in the liquid.
* Several levels can be monitored by several reed contacts in the guide tube even with one float.
* Suitable for any fluid compatible with material of construction and sp. Gravity above 0.7.
* These Switches operate in any position - from vertical to an inclined angle of 45°, head assembly upward or downward.
* Closing, opening or change-over contacts can be selected.
* Factory-set level actuation points can be easily adjusted at site.
* Minimum possible actuating distance from top of connection is 30 mm.
* Factory-set level actuation points can be easily adjusted at site.
* Minimum possible actuating distance from top of connection is 30 mm.
* Minimum possible distance between 2 level set points is 75 mm, if 2 independent floats are used.
* All the floats and stoppers can be removed thro' bottom side of stem, if necessary, for easy installation in your vessel and retain them to their original positions. |
INFORMATION REQUIRED TO QUOTE
Materials of construction, service medium with sp. Gravity and other parameters of service conditions, number of actuating levels and their distances from top of connection and type of process connection. Also specify the condition of each switch required whether switch should close 1 open on fall 1 rise of level
|
|
 |
| << Back |
|
|
|
|